Test Code LAB90 Hemoglobin A1C
Additional Codes
CPT Code: 83036
Performing Laboratory and Testing Schedule
TidalHealth Peninsula Regional - Special Chemistry
Monday to Friday specimens collected on those days must be received by 1800 to be tested that day.
Weekend - Samples collected must be received by 1200 to be tested that day.
Schedule is subject to change based on holidays, instrumentation issues, and reagent availability.
Specimen Requirements
Draw blood in a lavender-top (EDTA) tube, and send 2 mL of EDTA blood refrigerated.
Note: 1. Fasting is not required for this test.
2. Specimen is stable at ambient temperature for 24 hours.
Reference Values
≤ 6.0%
HbA1c values are lowered in hemolytic anemia because of shortened life of erythrocytes. Iron Deficiency can lead to a decreased erythrocyte mass. In either case, average age of erythrocytes is altered. Caution should be exercised when interpreting HbA1c results from patients with these conditions, and when total hemoglobin is < 9 g/dL.