Test Code LAB345 AUTOANTIBODIES TO SS-B/LA

Additional Codes

CPT Code: 86235

Methodology

Multiplex Flow Immunoassay

Performing Laboratory

Peninsula Regional Medical Center - Serology

Specimen Requirements

Draw blood in a tiger-top or a serum get tube. Spin down and send 0.5 mL (minimum volume: 0.2 mL) of serum refrigerated.

Reference Values

<100 AU/mL: negative

100-120 AU/mL: equivocal

>120 AU/mL: positive

Reference values apply to all ages.

Day(s) Test Set Up

Monday, Wednesday, Friday