Test Code LAB000 - Enter Specimen type, Source, and Test Name Factor VII Inhibitor Screen, Plasma
Additional Codes
Mayo test code: F7_IS
Method Name
Only orderable as part of a profile. For more information see:
7INHE / Factor VII Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
Optical Clot-Based
Reporting Name
Factor VII Inhib ScrnSpecimen Type
Plasma Na CitSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Reference Values
Only orderable as part of a profile. For more information see:
7INHE / Factor VII Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
Negative
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
85335
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F7_IS | Factor VII Inhib Scrn | 81123-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
7810 | Factor VII Inhib Scrn | 81123-2 |
Specimen Required
Only orderable as part of a profile. For more information see:
7INHE / Factor VII Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
For more information see Coagulation Guidelines for Specimen Handling and Processing.
Useful For
Detecting the presence of a specific factor inhibitor directed against coagulation factor VII