Test Code LAB000 HLA B High Resolution
Additional Codes
FHLAB
Specimen Required
Histocompatibility Lab Transplant Testing Requisition is required.
Draw blood in a lavender-top (EDTA) tube(s).
Send 14 mL of EDTA whole blood at ambient temperature.
Special Instructions
Method Name
PCR and Direct DNA Sequencing
Reporting Name
HLA B High ResolutionSpecimen Type
Whole Blood EDTASpecimen Minimum Volume
5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole Blood EDTA | Ambient | 14 days |
Reject Due To
Hemolysis | Reject |
Reference Values
Testing is complete. Final report has been sent to the referring laboratory.
Day(s) Performed
Varies
Report Available
7 to 11 daysPerforming Laboratory
Versiti Wisconsin, Inc.Test Classification
This test was developed and its performance characteristics determined by Versiti Wisconsin, Inc. It has not been cleared or approved by the US Food and Drug Administration. This test is used for clinical purposes. It should not be regarded as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing.CPT Code Information
81380
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FHLAB | HLA B High Resolution | 45028-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z0130 | HLA B High Resolution | 45028-8 |
Z0119 | Comments: | 48767-8 |